▸ ROOT / HARDWARE/ RMM SCANNER

RMM Scanner

RMM Scanner hardware documentation.

▸ BETA

CE-103000

The Rack-Mounted Module (RMM) Scanner is Cheetah's inspection platform for server, networking, and other rack-mounted hardware. A Cartesian motion system positions laser profilometers and color cameras across the connector end of the product. The profilometers capture three-dimensional surface measurements, while the cameras provide images for visual review.

This page is the primary hardware manual for the CE-103000 RMM Scanner platform. It covers the physical machine, receiving and installation, electrical power, operator controls, product loading, customer-facing hardware interfaces, and basic care of the system.

Application-specific trays, positioning hardware, sensors, and material-handling arrangements may vary between systems and are documented separately when required. Detailed operation of the Cheetah software, inspection programs, and developer interfaces is covered in the corresponding software and developer documentation.

System Identification#

Each RMM Scanner has a unique system serial number used to identify the machine for service, support, configuration records, and replacement parts.

The serial number is marked in two locations:

  • Chassis marking - permanently laser cut into the chassis on the left side of the machine, visible through a cutout in the left-hand cover.
  • Identification label - located on the inside of a control cabinet door and shows both the system serial number and system part number.

CE-103000 identifies the RMM platform. The system part number on the identification label identifies the configured machine; use it together with the serial number when requesting support.

System Layout#

The RMM Scanner is organized around a front workstation for product loading and operator interaction, and a rear sensor station containing the Cartesian motion and inspection hardware.

[IMAGE PLACEHOLDER: RMM-IMG-001]

Major hardware areas of the CE-103000 RMM Scanner.

The major machine areas are:

  • Front workstation - supports products and their trays or other application-specific interfaces.
  • Roller-conveyor loading surface - allows products to be transferred into and out of the inspection area.
  • Rear sensor station - supports the Cartesian motion system, laser profilometers, and color cameras.
  • Touchscreen - industrial display running the Cheetah operator interface.
  • Operator panel - controls distributed across left and right front sections, with an emergency-stop button on each side.
  • Status lights - front RGB light strips for visible machine-state indication.
  • User expansion panel - left-side customer interface for networking, USB, safety, and discrete I/O.
  • Control cabinet - front-mounted, two-door electrical cabinet containing the system controls and electronics.
  • Side covers - left and right end covers that help prevent trays and products from rolling off the loading surface when raised, and can be lowered for product transfer.
  • Rear cover - provides service access to the internal motion and sensor systems.

Receiving and Unboxing#

The RMM Scanner ships secured to a wooden base inside a crate with a removable roof and four walls, fastened with metal clips or screws.

Shipping dimensions

Specification Value
Width 243.8 cm (96 in)
Depth 121.9 cm (48 in)
Height 152.4 cm (60 in)
Maximum shipping weight Approximately 400 kg

To unbox the machine:

  1. Remove the roof and walls by releasing the metal clips or removing the screws.
  2. Remove the lag screws securing the shipping mounts to the wooden base. Leave the mounts attached to the chassis.
  3. Lift the machine from the wooden base using an appropriately rated forklift.
  4. Place the machine on a smooth, hard surface.
  5. Remove the shipping mounts from the chassis using a 4 mm hex key.
  6. Roll the machine into position using the integrated casters.
  7. Retain the shipping mounts for future transportation.

[IMAGE PLACEHOLDER: RMM-IMG-003]

RMM Scanner crate, shipping mounts, and unboxing arrangement.

Mechanical Installation#

Positioning and Leveling#

Install the machine on a stable, smooth, hard floor. The integrated casters allow the machine to be rolled into position.

Once positioned, lower the leveling feet until the rubber pads contact the floor and the machine is stable and level. The leveling feet also provide fine height adjustment.

Height adjustment spacers

For coarse height adjustment, spacers can be installed between the chassis and the caster/leveling-foot assemblies to align the RMM with surrounding roller conveyors. The spacers use M8-1.25 mounting hardware.

Cheetah Part Number Spacer Thickness
CE-310223 3 mm
CE-310222 6 mm
CE-310008 12 mm
CE-310009 25 mm
CE-410224 100 mm

Position the RMM relative to surrounding equipment to accommodate product transfer and access to the operator controls, user expansion panel, and front control cabinet.

The removable rear cover provides access to the sensors and actuators for occasional service. The machine can be positioned against a wall or adjacent equipment, but may need to be moved when rear access is required.

Side cover positioning

The left and right covers at the ends of the roller-conveyor loading surface act as guards in the standard raised position, helping prevent trays and products from rolling off the conveyor ends. Either cover can be lowered to accommodate product transfer.

The covers can be configured with:

  • Both covers raised - a contained loading surface.
  • Either the left or right cover lowered - product entry or exit from that side.
  • Both covers lowered - through-flow material handling.

To lower either cover:

  1. Remove the mounting screws using a 4 mm hex key.
  2. Move the cover to the lower mounting holes, located several centimeters below the standard position.
  3. Reinstall and secure the mounting screws.

When lowered, the upper edge of the cover is approximately level with the roller-conveyor surface.

Touchscreen Installation#

The RMM Scanner supports six touchscreen mounting configurations using a fixed mount or an articulated arm.

Mounting Method Location
Fixed mount Upper surface, left
Fixed mount Upper surface, right
Articulated arm Upper surface, left
Articulated arm Upper surface, right
Articulated arm Lower front, left
Articulated arm Lower front, right

The lower front positions are beside the operator controls on the movable left and right operator-panel sections.

Mounting components

Component Cheetah Part Number
Fixed touchscreen mount CE-300865
Articulating positioning arm CE-700371
Aluminum positioning-arm adapter CE-300866

The articulated installation uses the positioning arm and aluminum adapter.

After mounting, route and secure the cables so the display can be positioned without interference with product transfer, operator controls, or moving hardware.

[IMAGE PLACEHOLDER: RMM-IMG-006]

All six RMM touchscreen mounting configurations, including upper-surface and lower-front locations.

Electrical Power#

The base RMM Scanner is designed to operate from a standard 110-120 VAC outlet on a 15 A or greater circuit.

The machine power cord terminates in a standard NEMA 5-15 plug. The cord is routed from the user-panel area and can exit through the side of the machine or downward toward floor-level power.

Application-specific hardware may change the final electrical requirements. Use the electrical requirements provided for the configured system.

Normal daily startup and shutdown are performed using the system power switch on the operator panel.

⚠️ Power and Connection Warnings

Warning: Do not disconnect a laser profilometer while the system is powered. Disconnecting the sensor under power can damage the sensor.

Warning: Do not unplug the machine power cord until the system power switch is in the OFF position and the industrial PC has fully shut down.

Operator Interface#

Touchscreen#

The industrial touchscreen runs the Cheetah operator interface and serves as the primary user interface for operating the system.

Inspection-program selection, inspection results, and other software functions are described in the corresponding software documentation.

Operator Panel#

The operator panel groups the main day-to-day hardware controls across the left and right front sections to suit the machine's width.

Left section:

  • System power switch - illuminated on/off switch for quick daily startup and managed shutdown, preventing accidental hard power-offs.
  • Emergency stop - local emergency-stop button.

Right section:

  • Emergency stop - local emergency-stop button.
  • Two high-speed USB 3 ports - convenient front access for temporary peripherals such as a keyboard, mouse, barcode scanner, or external storage device.

[IMAGE PLACEHOLDER: RMM-IMG-007]

Left section: system power switch and emergency stop. Right section: emergency stop and two USB 3 ports. Front RGB status lighting is also shown.

Status Lighting#

Two front RGB light strips provide visible machine-state indication.

The lighting is software controlled and customizable for the application. Typical states may include:

  • Ready or idle.
  • Inspection in progress.
  • Inspection complete.
  • Operator attention required.
  • Fault or safety stop.
  • Pass/fail indication.

Color assignments and indication patterns depend on the configured application.

Product Loading and Interfaces#

The standard front workstation provides a roller-conveyor surface for loading and unloading products. It can interface with surrounding material-handling equipment.

The raised side covers help contain trays and products on the loading surface. Lower either cover for entry or exit from that side, or lower both for through-flow material handling. The repositioning procedure is described under Positioning and Leveling.

Trays, locating features, retention hardware, and other product interfaces are selected for the application. These interfaces establish a repeatable relationship between the product and the inspection system.

Use the product orientation, positioning, and handling instructions provided for the configured interface. Product dimensions, tray geometry, and load capacity must be compatible with the installed arrangement.

Cheetah can adapt the material-handling arrangement for powered conveyors or automated loading and unloading. These configurations may use a different product-support interface in place of the standard front roller-conveyor assembly.

[IMAGE PLACEHOLDER: RMM-IMG-008]

Roller-conveyor loading surface, product interface, and raised and lowered side-cover positions.

User Expansion Panel#

The user expansion panel is located on the left side of the machine and is the primary customer-facing hardware integration point for the RMM Scanner.

It is recessed into the machine structure to protect connectors and cable ends while allowing convenient access. Cables can be routed out through the side opening or downward toward the floor.

[IMAGE PLACEHOLDER: RMM-IMG-010]

Left-side user expansion panel and external connections.

The panel includes:

  • USB - three USB ports for accessories and permanently or semi-permanently connected peripherals.
  • LAN - two Ethernet ports for sensors, cameras, controllers, and other machine-level devices.
  • WAN - 2.5 Gbit/s Ethernet connection for the customer's network, intranet, MES, or other higher-level systems.
  • Safety In - dual-channel external safety input for an emergency stop, interlock, or master safety system.
  • Safety Out - dual-channel dry-contact interface for local emergency-stop status.
  • User I/O - five PNP-compatible 24 VDC inputs and five relay-switched PNP outputs for sensors, actuators, indicators, and PLC integration.

Safety Input#

The Safety In connection allows the RMM Scanner to be incorporated into an external emergency-stop, interlock, or master safety system.

The input uses two independent normally closed (N.C.) channels. Each channel is completed by a contact between its A and B terminals: Channel 1A to Channel 1B, and Channel 2A to Channel 2B.

When an external safety circuit is not required, the supplied safety bypass (CE-310190) completes both channels. The bypass uses a field-serviceable connector and can also be rewired for connection to customer safety equipment.

Item Specification
Machine connector CE-600183 (Phoenix Contact 1419328)
Connector type 5-position M12 A-coded, female
Used contacts 4; center contact unused
Signal Dual-channel, N.C.
External circuit electrical limits TBD
Field-serviceable connector CE-610185 (Manufacturer PN TBD)
3 m cable with flying leads Cheetah PN TBD (Manufacturer PN TBD)

Safety Input Pinout

Pin Function
1 Safety Channel 1B
2 Safety Channel 2A
3 Safety Channel 2B
4 Safety Channel 1A
5 Not connected

Each safety channel is completed by a normally closed contact between its A and B terminals:

  • Channel 1: pins 4 and 1.
  • Channel 2: pins 2 and 3.

Connector compatibility: The Safety In interface uses a 5-position M12 A-coded socket, with the center contact unused. It can be used with the supplied 4-position male bypass connector or a compatible 5-position male connector or cable.

Safety Output#

The Safety Out connection provides two independent dry-contact channels for integration of local emergency-stop status with an external safety system.

Item Specification
Machine connector CE-600184 (Phoenix Contact 1419409)
Connector type 5-position M12 A-coded, male
Used contacts 4; center contact unused
Signal Dual-channel dry-contact E-stop status
Contact electrical ratings TBD
Field-serviceable connector Cheetah PN TBD (Phoenix Contact 1662968)
3 m cable with flying leads Cheetah PN TBD (Phoenix Contact 1669835)

Safety Output Pinout

Pin Function
1 Safety Channel 1B
2 Safety Channel 2A
3 Safety Channel 2B
4 Safety Channel 1A
5 Not connected

Each output channel provides a dry contact between its A and B terminals:

  • Channel 1: pins 4 and 1.
  • Channel 2: pins 2 and 3.

Connector compatibility: Requires a 5-position M12 A-coded female mating connector or cable. Pin 5 is not connected.

User I/O#

The User I/O connection provides five general-purpose inputs and five outputs for integrating sensors, actuators, indicators, PLCs, and other external equipment.

The interface uses customer-supplied 24 VDC field power.

The five inputs accept PNP-compatible 24 VDC signals. The five outputs use internal normally-open relays to switch the customer-supplied 24 VDC field power.

Item Specification
Machine connector CE-600185 (Phoenix Contact 1442188)
Connector type 12-position M12 A-coded, female
Inputs 5 PNP-compatible 24 VDC inputs
Outputs 5 relay-switched PNP outputs
Field power Customer-supplied 24 VDC and 0 VDC
Maximum output current 1.0 A combined across all outputs
3 m cable with flying leads Cheetah PN TBD (Phoenix Contact 1430543)

Note: The 1.0 A output limit is shared across all five outputs. Higher-current loads should be controlled using an external relay or other appropriately rated interface.

User I/O Pinout

Pin Function
1 External +24 VDC
2 External 0 VDC
3 User Input 1
4 User Input 2
5 User Input 3
6 User Input 4
7 User Input 5
8 User Output 1
9 User Output 2
10 User Output 3
11 User Output 4
12 User Output 5

Note: Pins 1 and 2 are field-power connections supplied by the customer's external system. The User I/O connector does not provide 24 VDC accessory power from the RMM Scanner.

Control Cabinet#

The RMM Scanner uses a front-mounted, two-door control cabinet.

The cabinet contains the industrial computer, networking hardware, safety controls, I/O controller, power distribution, motion-control hardware, and sensor controllers required by the configured system.

[IMAGE PLACEHOLDER: RMM-IMG-013]

Front control cabinet and major internal components.

⚠️ WARNING - Risk of electrical shock

Disconnect machine power before opening the control cabinet or servicing internal components. Hazardous voltage may be present inside the cabinet whenever the machine is connected to facility power, even when the system is switched off.

The control cabinet is part of the RMM Scanner's factory-integrated control system and is not intended as a general-purpose enclosure for customer modification or third-party equipment integration unless otherwise expressly approved by Cheetah. Customer equipment should normally interface with the system through the touchscreen, operator panel, user expansion panel, and documented software interfaces rather than through internal cabinet wiring.

The cabinet includes the system's main circuit breaker, which may require access for service or recovery. The power-disconnection warning above applies to this access.

The cabinet also accommodates application-specific hardware integrated by Cheetah or installed as part of an approved system configuration, such as additional sensor controllers, communications hardware, or I/O equipment.

Care and Maintenance#

Key care and maintenance requirements include:

  • Keep the workstation, roller-conveyor surface, and product-positioning features clean.
  • Keep the laser profilometers and camera windows clean and protected from contamination. Follow the sensor manufacturer's cleaning instructions.
  • Operate the system in a clean, temperature-controlled indoor environment.
  • Refer to the sensor and motion-equipment documentation for component-specific maintenance requirements.
  • Reposition or adjust inspection sensors, motion hardware, and product-positioning components only with guidance from Cheetah.

Disconnect machine power before removing the rear cover or servicing internal components. Also isolate customer-supplied field power before servicing connected User I/O equipment.

Technical Specifications#

Specification Value
Product name Rack-Mounted Module (RMM) Scanner
Product number CE-103000
Input power, base system 110-120 VAC
Minimum circuit rating, base system 15 A
Power plug, base system NEMA 5-15
Motion system Cartesian motion
Laser profilometers Application-specific models
Color cameras Application-specific
Product loading Roller-conveyor surface; configurable product and material-handling interfaces
Touchscreen mounting Six configurations; upper fixed/arm mounts and lower-front arm mounts, left or right
Operator panel Left: power switch and E-stop; right: E-stop and two USB 3 ports
Status lighting Two front RGB strips; software-controlled, application-specific indications
Control cabinet Front-mounted, two doors
User expansion panel Left side
User I/O 5 PNP-compatible inputs, 5 relay-switched PNP outputs
User I/O field power Customer-supplied 24 VDC
Maximum User I/O output current 1.0 A combined across all outputs
Customer network 1 x 2.5 Gbit/s Ethernet
Device network 2 x Ethernet
External safety input Dual-channel N.C. contact interface
Local E-stop status output Dual-channel dry contacts
Overall dimensions (W x D x H) TBD
Machine weight TBD
Supported product and tray envelope Defined for the configured product interface
Maximum supported load, including tray Refer to the configured system documentation
Roller height and adjustment range Defined for the installation; coarse adjustment with spacers and fine adjustment with leveling feet

Application-specific hardware may change the final dimensions, weight, electrical requirements, and product-handling limits. Refer to the documentation supplied for the configured system.

▸ LAST VERIFIED Thu Aug 13 2026 00:00:00 GMT+0000 (Coordinated Universal Time) ▸▸ /content/hardware/rmm-scanner.md
▸ DOCS UNDER CONSTRUCTION LAST UPDATED 2026-11-18 ▸ CHANGELOG